95
area (1).
2.
In the viewing tile (2) set the nodes of the area, in order, in which the situation requires
analysis.
Note
When the area is being constructed, the nodes are connected by a
two-
color dotted line which outlines the area's borders
Action Result
Left-click in the viewing tile Creates a new area node
Right-click on a created node Deletes the area node
Position the cursor on a node and hold
down the left mouse button while you move
the mouse
Moves the area node
Click the button
Deletes the area
3.
Click the Apply button.
The area is now set.
Settings Specific to Loitering Detection
When configuring the Loitering detection tool, you must set the maximum time an object can be
in the analyzed area: when the maximum time is exceeded, the detection tool is triggered.
To set a maximum time, you must perform the following steps:
1.
In the Detection Tools list, highlight a Loitering object (1).